  • Chromatography Vials, Caps & Septa Autosampler Vials for HPLC & GC Aijiren's autosampler vials are available as either snap, screw or crimp in style. Most users will be familiar with the main 2 mL vial being the HPLC vial or LC/MS vial; sometimes being referred to as a 1.5 mL vial.

  • Comprehensive Guide to Syringe Filters: Features, Selection, Price, and Usage HPLC Vial Inserts: Enhancing Precision and Sample Integrity Premium PTFE and Silicone Septa: Reliable Sealing Solutions Wholesale COD-V50 16mm 100mm cod tube for water analysis V945 Cheap 2ml 9mm amber HPLC vials for sale V935 Wholesale 2ml amber HPLC vials from China V917 China 2ml 9mm chromatography vails factory

  • Jul 31, 2020 · Needle Gauge: A bigger needle gauge can need more force to get through non-pre-slit septa, which could cause damage to the septa or sample contamination. A pre-slit septum might be the best choice in this situation. Injection Frequency: A pre-slit septa may be more appropriate for applications requiring repeated injections since it can lessen

  • A specially moulded seal with a PTFE insert. Sealing surface of Butyl and PTFE affects a more positive seal than non-PTFE-faced septa. Ideal choice for temperatures below 125°C. Good sealing characteristics, excellent resistance to most solvents with reduced coring and high puncture tolerance.

  • PTFE/silicone septa are always best. What force is required to penetrate the septum? Generally, silicone septa are more easily pierced than red rubber or butyl septa. For thicker, hard-to-pierce septa, a small gauge (23 gauge) needle may be required, or a stronger S-needle can be used. Preslit septa are the best option for

  • Oct 19, 2015 · The first OOS occurred when a chemist used the caps with non-cut septa on the Shimadzu HPLC. All vials had the first injections with significantly lower areas than the following injections. Prior to this OOS, we allocated the caps with non-cut septa for the Dionex HPLC, and the caps with pre-cut septa for the Shimadzu HPLC.

  • Oct 20, 2021 · Aijiren cap septa offers new septum materials and unique processes to improve septum sealing integrity and reduce the risk of sample contamination. Septa are 0.035” Natural Silicone with 0.005” Natural PTFE. High quality silicone is used to ensure proper re-sealing and reduced coring. Designed for multiple injections and/or longer sample

  • Zhejiang Aijiren is the leading hplc septa supplier and manufacturer,welcome to inquiry hplc septa from us. E-mail:market@aijirenvial.com Whatsapp:+8618057059123

  • 2ml Amber Screw HPLC Vials, caps, septa, and inserts working as a whole to prevent sample degradation and loss of samples caused by evaporation. Screw thread closures N9 (9mm) 2ml vials and closures are universally suitable on most autosamplers, convenient in handling and available in a broad selection of different cap colors and septum materials.

  • Polyethylene (PE) septa and integral molded closures Chemically resistant polyethylene septa are molded into single-piece caps. The surface for needle penetration is 0.01" thick, allowing for use with most HPLC autosamplers. Polyethylene septa are not resealable and are intended for single injection use with aqueous based sample mixtures.

  • the solvent. PTFE/Silicone septa are ideal for use in most HPLC and GC applications where resealability and purity are critical. Pre-slit PTFE/silicone septa Pre-slit septa are offered in many of the same formulations as for non-slit PTFE/silicone septa and shares most of the physical and chemical characteristics.

  • Dec 21, 2021 · Having the preslit septa helps ensure reproducibly in sample draw from the vial. The preslit septa are compatible with different autosampler injector needle materials like PEEK and metal-tipped. You may not want to use a preslit septa if your sample diluent is extremely volatile or if samples are heated.

  • Alliance HT HPLC Systems. This vial delivers maximum sample capacity (~1.5 mL) with minimum residual volume. The 9 mm cap makes it ideal for use with Aijiren HPLC and GC Systems. Choosing the level of certified vial should be based on the concentration of analyte. Concentration of analytes is often tied closely with the detection source used.

  • There are a lot of factors to consider when selecting a chromatography vial. Aijiren Tech offers a large selection of 0mm 10-425 HPLC vials and closures, including HPLC vials, inserts, caps, and septa to suit your analytical needs. Vial Dimension: 11.6*32mm Vial Volume: 1.5-2.0ml Cap: Plastic open/solid cap Septa: Non-slit, Pre-Slit, PTFE/Silicone

  • On most of the HPLC septa, the white surface is the Teflon side, so face it towards the liquid sample, but check with the supplier you use as this varies a lot (e.g. Aijiren sells both red and